TY - JOUR T1 -纤维支气管镜吸入通道污染引起的血吸虫分枝杆菌感染的假流行JF -欧洲呼吸杂志JO - Eur Respir J SP - 1259 LP - 1262 DO - 10.1183/09031936.95.08081259 VL - 8 IS - 8 AU - Wang, HC AU - lilaw, YS AU - Yang, PC AU - Kuo, SH AU - Luh,KT Y1 - 1995/08/01 UR - //www.qdcxjkg.com/content/8/8/1259.abstract N2 - 1992年9月至12月在国立台湾大学医院支气管洗液标本中发现龟分枝杆菌亚种龟分枝杆菌分离频率异常增加。在此期间,共有123名患者使用奥林巴斯P20进行了纤维支气管镜检查。76例患者行支气管清洗,进行细菌学和细胞学检查。在21例患者中发现了抗酸杆菌,其中18例从支气管洗涤培养中分离出龟分枝杆菌。8例患者因不明原因肺部病变、耐酸染色及龟分枝杆菌培养阳性,被诊断为分枝杆菌感染。一名患者的肺癌诊断因最初的细胞学研究阴性和细菌培养阳性而延迟。纤维支气管镜用自动洗衣机(EW-20, Olympus)按标准方案使用2.3%戊二醛消毒。通过调查寻找可能的污染源,他们在四种不同的支气管镜的吸入通道中被识别出来。这次事件被证明是一场假流行病。 The contamination was controlled by extensive suction and rinsing of the channel with 70% alcohol immediately after disinfection by the automated bronchoscope disinfection machine. This study shows that, despite using the disinfection machine, the suction channel could still be contaminated with Mycobacterium chelonae. This may cause diagnostic confusion and unnecessary antimycobacterial treatment. ER -